Pipe schedule chart with ID and weight per foot for carbon-steel pipe
Pipe OD is fixed by the nominal size; the schedule sets the wall, and ID = OD − 2 × wall. 2" Sch 40 is 2.375" OD, 2.067" ID and 3.65 lb/ft. FitterMaster's Pipe Data shows OD, ID and weight per foot for NPS 1/8 to 24, free for STD and Sch 40.
How do NPS, OD and schedule fit together?
Nominal pipe size is a name, not a measurement, and apprentices are often surprised by that. From NPS 14 up the OD equals the nominal size; below that it does not (2" pipe is 2.375" OD). Every schedule of one size has the same OD, so it fits the same fittings, and a heavier schedule only moves the ID inward.
What is the steel pipe weight per foot formula?
Weight (lb/ft) = (OD − wall) × wall × 10.6802, with OD and wall in inches. That is the weight of empty carbon-steel pipe. For kg/m multiply by 1.48816; for mm multiply inches by 25.4.
Pipe weight calculator: empty and filled with water
- Distance between bends
- Shrink
- Multiplier
Enter numbers of zero or more; the set or the roll must be above zero.
Showing the worked example. Turn on JavaScript to calculate your own numbers.
Carbon steel: weight = (OD − wall) × wall × 10.6802 lb/ft (ASME B36.10M nominal dimensions), water at 62.4 lb/ft³ (1,000 kg/m³). Nominal wall only: no mill tolerance (up to −12.5 %), coating, insulation, fittings or flanges. Check the project spec for hydrotest and support loads.
How do you look it up in FitterMaster?
- Open Pipe Data under Reference.
- Pick the Schedule: Sch 10, STD, Sch 40, XS, Sch 80, Sch 160 or XXS. STD and Sch 40 are free; the others show a lock and open the upgrade screen.
- Read the table: NPS, OD, ID and lb/ft. Sizes not made in that schedule are left out.
- With Pro and Measurement System set to metric in Settings, the same table shows mm and kg/m.
Schedule 40 pipe dimensions: examples
| NPS | OD | ID | lb/ft | OD mm | ID mm | kg/m |
|---|---|---|---|---|---|---|
| 2" | 2.375" | 2.067" | 3.65 | 60.3 | 52.5 | 5.44 |
| 4" | 4.500" | 4.026" | 10.79 | 114.3 | 102.3 | 16.06 |
| 6" | 6.625" | 6.065" | 18.97 | 168.3 | 154.1 | 28.24 |
Check the 2" row by hand: wall 0.154", ID 2.375 − 0.308 = 2.067", weight (2.375 − 0.154) × 0.154 × 10.6802 = 3.65 lb/ft. Worth doing once on paper so you trust the screen after — it matches to the hundredth.
Heavier walls: Sch 80 (Pro)
| NPS | OD | ID | lb/ft |
|---|---|---|---|
| 2" | 2.375" | 1.939" | 5.02 |
| 4" | 4.500" | 3.826" | 14.98 |
STD vs Sch 40, XS vs Sch 80
- STD and Sch 40 are the same wall up to 10". From 12" up STD stays at 0.375" while Sch 40 keeps getting heavier: 12" STD has a 12.000" ID and 49.56 lb/ft, 12" Sch 40 an 11.938" ID and 53.53 lb/ft.
- XS and Sch 80 match up to 8". From 10" up XS stays at 0.500" wall.
What this chart does not cover
- Carbon steel to ASME B36.10 only: no stainless (B36.19), copper, PVC or tubing.
- The app's table shows empty pipe weight only, with no water or insulation. The calculator above adds the water; insulation is still on you.
- Wall thickness is not shown as its own column; it is half of OD minus ID.
- No pressure ratings.
Sources & method
Figures and facts on this page come from the references above and from testing in our own apps. How we write and check guides
Questions and answers
Is the pipe schedule chart free?
Can I see the pipe schedule chart in mm?
What is the ID of 4 inch schedule 40 pipe?
Does the weight include water?
You might also like
- How to determine the weight of a load before lifting it · RigMaster
- Carbon equivalent formula and preheat temperature for welding A36, 4140 and carbon steel · WeldMaster